Forums › General Discussion › Battery banks

Viewing 1 reply thread
  • Author
    Posts
    • #67139
      RLeeds
      Participant

      Just got back from a 10 day trip to the Vineyard and Cape. Noticed that at the end of each day when I went to charge batteries, one bank always took about twice the amperage of the second bank, even though both banks were placed in parallel at all times to increase the overall amp hours of the now one bank. Banks are identical, 2 Trojan T-105’s in each bank yielding a total of 425 Ah.

      Would one suspect that the bank that is not being drawn down as far is failing, or not up to snuff? I find this very curious!

      Thanks for your thoughts.

      Rodd Leeds
      Windseeker

      Post generated from Pearson424 Forum using Mail2Forum

    • #70532
      madsailor
      Moderator

      Hi Rodd,

      I'd first check the connections on the batteries to make sure there's no corrosion. Then, it sounds like one bank is weak. It would draw down quicker because it doesn't hold a charge properly.

      That's my guess.

      Bob

      On Sun, Aug 31, 2008 at 3:03 PM, Rodd Leeds wrote:

      Just got back from a 10 day trip to the Vineyard and Cape. Noticed that at the end of each day when I went to charge batteries, one bank always took about twice the amperage of the second bank, even though both banks were placed in parallel at all times to increase the overall amp hours of the now one bank. Banks are identical, 2 Trojan T-105's in each bank yielding a total of 425 Ah.

      Would one suspect that the bank that is not being drawn down as far is failing, or not up to snuff? I find this very curious!

      Thanks for your thoughts.

      Rodd Leeds
      Windseeker

      —
      Bob Fine
      Fine Software LLC
      Your data on the web your way. No kidding

      Post generated from Pearson424 Forum using Mail2Forum

Viewing 1 reply thread