Forums › General Discussion › Water tank vents

Viewing 12 reply threads
  • Author
    Posts
    • #67441
      Syringa
      Participant

      I don’t like the settee water tanks dumping over flow water into the fwd bilge. I have been thinking about rerouting the vent lines into the upper anchor locker and letting them drain there. Any other ideas?

    • #72307
      madsailor
      Moderator

      That’s a great idea, although it may leave loops or sags in the line.
      I extended(replaced) mine to lead back to the aft bilge, where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are exposed to
      seawater. And then there is the issue of tank pressure-the highest
      point of the vent provides about 1/2 lb/ft, which translates to
      pressure throughout the tank. The tanks don’t look to sturdy to me…

      Bob

      On 3/31/09, Syringa <> wrote:

      I don’t like the settee water tanks dumping over flow water into the fwd
      bilge. I have been thinking about rerouting the vent lines into the upper
      anchor locker and letting them drain there. Any other ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail:
      For additional commands, e-mail:

      Post generated from Pearson424 Forum using Mail2Forum

    • #72308
      john stevenson
      Participant

      Bob,
      I assume you ran the vents directly to the bilge, with no loop to deck level.  Sounds like a good idea.  Even the original owners manual warned of over-filling the tanks and leaving water standing in the fill tube.  I think the combined diameter of the fill (1.5″) and the vent (0.5″) tubes would produce more hydrostatic pressure than .5 lb/ft. 
      Thanks, for another project.  While in the Bahamas there is no danger of me overfilling the tanks with $0.20/gallon water and watching it flow out through the bilge pump.  I monitor the filling very closely to avoid that situation.  Back in the states, with no additional charge for water at most marinas, I'm not always that careful.

      John

      On Wed, Apr 1, 2009 at 8:00 AM, Robert Fine < ([email][/email])> wrote:

      That's a great idea, although it may leave loops or sags in the line.
      I extended(replaced) mine to lead back to the aft bilge, where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are exposed to
      seawater. And then there is the issue of tank pressure-the highest
      point of the vent provides about 1/2 lb/ft, which translates to
      pressure throughout the tank. The tanks don't look to sturdy to me…

      Bob

      On 3/31/09, Syringa < ([email][/email])> wrote:

      I don't like the settee water tanks dumping over flow water into the fwd
      bilge.  I have been thinking about rerouting the vent lines into the upper
      anchor locker and letting them drain there.  Any other ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail: ()
      For additional commands, e-mail: ()

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      Post generated from Pearson424 Forum using Mail2Forum

    • #72311
      madsailor
      Moderator

      Hi John,

      No, you do need a loop, at least as high above the tank as the distance from the vent to the edge of the tank (so it doesn't siphon when heeled).  You can meet the criteria by laying the vent across the tank, looping it back to the other side of the tank and then to the bilge.  Just so water can't flow out when heeled at the maximum angle. 

      As far as the fill line and vent being filled above the tank, it doesn't matter whether you have a 1-1/2″ tube or a 1/2″ tube.  The first law of hydraulics is that pressure in one point of a system is identical in all points of the system.  The pressure applied to the tank has nothing to do with the volume of water – just the height of it.  It's non-intuitive, but true.

      Anyway, that's my story and I'm sticking to it.

      Bob

      On Wed, Apr 1, 2009 at 9:11 AM, John Stevenson < ([email][/email])> wrote:

      Bob,
      I assume you ran the vents directly to the bilge, with no loop to deck level.  Sounds like a good idea.  Even the original owners manual warned of over-filling the tanks and leaving water standing in the fill tube.  I think the combined diameter of the fill (1.5″) and the vent (0.5″) tubes would produce more hydrostatic pressure than .5 lb/ft. 
      Thanks, for another project.  While in the Bahamas there is no danger of me overfilling the tanks with $0.20/gallon water and watching it flow out through the bilge pump.  I monitor the filling very closely to avoid that situation.  Back in the states, with no additional charge for water at most marinas, I'm not always that careful.

      John

      On Wed, Apr 1, 2009 at 8:00 AM, Robert Fine < ([email][/email])> wrote:

      That's a great idea, although it may leave loops or sags in the line.
      I extended(replaced) mine to lead back to the aft bilge, where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are exposed to
      seawater. And then there is the issue of tank pressure-the highest
      point of the vent provides about 1/2 lb/ft, which translates to
      pressure throughout the tank. The tanks don't look to sturdy to me…

      Bob

      On 3/31/09, Syringa < ([email][/email])> wrote:

      I don't like the settee water tanks dumping over flow water into the fwd
      bilge.  I have been thinking about rerouting the vent lines into the upper
      anchor locker and letting them drain there.  Any other ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail: ()
      For additional commands, e-mail: ()

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      —
      Bob Fine
      s/v Pelican
      Hull #8

      Post generated from Pearson424 Forum using Mail2Forum

    • #72313
      john stevenson
      Participant

      Thanks, Bob.  Makes sense about the vent loop.  Avoiding the run into the forward cabin lockers will make things a lot easier and help keep moisture out of those lockers.
      The hydraulics issue I'll have to think about for awhile.

      John

      On Wed, Apr 1, 2009 at 10:51 AM, Robert Fine < ([email][/email])> wrote:

      Hi John,

      No, you do need a loop, at least as high above the tank as the distance from the vent to the edge of the tank (so it doesn't siphon when heeled).  You can meet the criteria by laying the vent across the tank, looping it back to the other side of the tank and then to the bilge.  Just so water can't flow out when heeled at the maximum angle. 

      As far as the fill line and vent being filled above the tank, it doesn't matter whether you have a 1-1/2″ tube or a 1/2″ tube.  The first law of hydraulics is that pressure in one point of a system is identical in all points of the system.  The pressure applied to the tank has nothing to do with the volume of water – just the height of it.  It's non-intuitive, but true.

      Anyway, that's my story and I'm sticking to it.

      Bob

      On Wed, Apr 1, 2009 at 9:11 AM, John Stevenson < ([email][/email])> wrote:

      Bob,
      I assume you ran the vents directly to the bilge, with no loop to deck level.  Sounds like a good idea.  Even the original owners manual warned of over-filling the tanks and leaving water standing in the fill tube.  I think the combined diameter of the fill (1.5″) and the vent (0.5″) tubes would produce more hydrostatic pressure than .5 lb/ft. 
      Thanks, for another project.  While in the Bahamas there is no danger of me overfilling the tanks with $0.20/gallon water and watching it flow out through the bilge pump.  I monitor the filling very closely to avoid that situation.  Back in the states, with no additional charge for water at most marinas, I'm not always that careful.

      John

      On Wed, Apr 1, 2009 at 8:00 AM, Robert Fine < ([email][/email])> wrote:

      That's a great idea, although it may leave loops or sags in the line.
      I extended(replaced) mine to lead back to the aft bilge, where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are exposed to
      seawater. And then there is the issue of tank pressure-the highest
      point of the vent provides about 1/2 lb/ft, which translates to
      pressure throughout the tank. The tanks don't look to sturdy to me…

      Bob

      On 3/31/09, Syringa < ([email][/email])> wrote:

      I don't like the settee water tanks dumping over flow water into the fwd
      bilge.  I have been thinking about rerouting the vent lines into the upper
      anchor locker and letting them drain there.  Any other ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail: ()
      For additional commands, e-mail: ()

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      —

      Bob Fine
      s/v Pelican
      Hull #8

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      Post generated from Pearson424 Forum using Mail2Forum

    • #72315
      john stevenson
      Participant

      I'm back with you on the pressure vrs weight.

      On Wed, Apr 1, 2009 at 11:32 AM, John Stevenson < ([email][/email])> wrote:

      Thanks, Bob.  Makes sense about the vent loop.  Avoiding the run into the forward cabin lockers will make things a lot easier and help keep moisture out of those lockers.
      The hydraulics issue I'll have to think about for awhile.

      John

      On Wed, Apr 1, 2009 at 10:51 AM, Robert Fine < ([email][/email])> wrote:

      Hi John,

      No, you do need a loop, at least as high above the tank as the distance from the vent to the edge of the tank (so it doesn't siphon when heeled).  You can meet the criteria by laying the vent across the tank, looping it back to the other side of the tank and then to the bilge.  Just so water can't flow out when heeled at the maximum angle. 

      As far as the fill line and vent being filled above the tank, it doesn't matter whether you have a 1-1/2″ tube or a 1/2″ tube.  The first law of hydraulics is that pressure in one point of a system is identical in all points of the system.  The pressure applied to the tank has nothing to do with the volume of water – just the height of it.  It's non-intuitive, but true.

      Anyway, that's my story and I'm sticking to it.

      Bob

      On Wed, Apr 1, 2009 at 9:11 AM, John Stevenson < ([email][/email])> wrote:

      Bob,
      I assume you ran the vents directly to the bilge, with no loop to deck level.  Sounds like a good idea.  Even the original owners manual warned of over-filling the tanks and leaving water standing in the fill tube.  I think the combined diameter of the fill (1.5″) and the vent (0.5″) tubes would produce more hydrostatic pressure than .5 lb/ft. 
      Thanks, for another project.  While in the Bahamas there is no danger of me overfilling the tanks with $0.20/gallon water and watching it flow out through the bilge pump.  I monitor the filling very closely to avoid that situation.  Back in the states, with no additional charge for water at most marinas, I'm not always that careful.

      John

      On Wed, Apr 1, 2009 at 8:00 AM, Robert Fine < ([email][/email])> wrote:

      That's a great idea, although it may leave loops or sags in the line.
      I extended(replaced) mine to lead back to the aft bilge, where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are exposed to
      seawater. And then there is the issue of tank pressure-the highest
      point of the vent provides about 1/2 lb/ft, which translates to
      pressure throughout the tank. The tanks don't look to sturdy to me…

      Bob

      On 3/31/09, Syringa < ([email][/email])> wrote:

      I don't like the settee water tanks dumping over flow water into the fwd
      bilge.  I have been thinking about rerouting the vent lines into the upper
      anchor locker and letting them drain there.  Any other ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail: ()
      For additional commands, e-mail: ()

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      —

      Bob Fine
      s/v Pelican
      Hull #8

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      —
      Regards,
      John Stevenson
      http://www.svsarah.com

      Post generated from Pearson424 Forum using Mail2Forum

    • #72316
      Anonymous

      Water tank vent should go up from the tank with a smaller hose and then
      loop down and dump into a larger tube, leaving an air gap, and thus a
      siphon break.

      John Stevenson wrote:

      Thanks, Bob. Makes sense about the vent loop. Avoiding the run into
      the forward cabin lockers will make things a lot easier and help keep
      moisture out of those lockers.
      The hydraulics issue I’ll have to think about for awhile.

      John

      On Wed, Apr 1, 2009 at 10:51 AM, Robert Fine <
      > wrote:

      Hi John,

      No, you do need a loop, at least as high above the tank as the
      distance from the vent to the edge of the tank (so it doesn’t
      siphon when heeled). You can meet the criteria by laying the vent
      across the tank, looping it back to the other side of the tank and
      then to the bilge. Just so water can’t flow out when heeled at
      the maximum angle.

      As far as the fill line and vent being filled above the tank, it
      doesn’t matter whether you have a 1-1/2″ tube or a 1/2″ tube. The
      first law of hydraulics is that pressure in one point of a system
      is identical in all points of the system. The pressure applied to
      the tank has nothing to do with the volume of water – just the
      height of it. It’s non-intuitive, but true.

      Anyway, that’s my story and I’m sticking to it.

      Bob

      On Wed, Apr 1, 2009 at 9:11 AM, John Stevenson
      < > wrote:

      Bob,
      I assume you ran the vents directly to the bilge, with no loop
      to deck level. Sounds like a good idea. Even the original
      owners manual warned of over-filling the tanks and leaving
      water standing in the fill tube. I think the combined
      diameter of the fill (1.5″) and the vent (0.5″) tubes would
      produce more hydrostatic pressure than .5 lb/ft.
      Thanks, for another project. While in the Bahamas there is no
      danger of me overfilling the tanks with $0.20/gallon water and
      watching it flow out through the bilge pump. I monitor the
      filling very closely to avoid that situation. Back in the
      states, with no additional charge for water at most marinas,
      I’m not always that careful.

      John

      On Wed, Apr 1, 2009 at 8:00 AM, Robert Fine <
      > wrote:

      That’s a great idea, although it may leave loops or sags
      in the line.
      I extended(replaced) mine to lead back to the aft bilge,
      where filling
      the tanks helps keep it clean and smelling fresh.

      There is some discussion about venting to areas that are
      exposed to
      seawater. And then there is the issue of tank pressure-the
      highest
      point of the vent provides about 1/2 lb/ft, which
      translates to
      pressure throughout the tank. The tanks don’t look to
      sturdy to me…

      Bob

      On 3/31/09, Syringa <
      > wrote:

      I don’t like the settee water tanks dumping over flow

      water into the fwd

      bilge. I have been thinking about rerouting the vent

      lines into the upper

      anchor locker and letting them drain there. Any other

      ideas?


      Don Gardner
      S/V Syringa #124

      /)+/)+~=:)

      —
      Sent from my mobile device

      Bob Fine
      s/v Pelican
      Hull #8


      To unsubscribe, e-mail:


      For additional commands, e-mail:

      —
      Regards,
      John Stevenson
      http://www.svsarah.com <http://www.svsarah.com>

      —
      Bob Fine
      s/v Pelican
      Hull #8

      —
      Regards,
      John Stevenson
      http://www.svsarah.com <http://www.svsarah.com>


      To unsubscribe, e-mail:
      For additional commands, e-mail:

      Post generated from Pearson424 Forum using Mail2Forum

    • #72318
      RichCarter
      Participant

      Don,
      The upper anchor locker can flood in heavy seas if water comes over the bow faster than it can drain out that little drain hole. I wouldn’t suggest putting your vent lines in there. If you haven’t already done it, I suggest sealing the small space under your toe rail above the forward bulkhead to keep water from entering the forward cabin.

      A friend with a Vagabond has his vent lines run up inside his stanchions. That’s kind of neat since it keeps them out of the way.

      Regards
      Rich
      BlackSheep #47


      Original Message


      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #72325
      sumocean
      Participant

      Basic physics question. Does a column of water 4″ in diameter 4′ high exert the same pressure as a 1″ column 4′ high?

      Linus

      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #72326
      madsailor
      Moderator

      Short answer: Yes – it is the column height that makes the pressure.

      Bob

      On Wed, Apr 1, 2009 at 1:28 PM, Linus Martinez < ([email][/email])> wrote:

      Quote:
      Basic physics question.  Does a column of water 4″ in diameter 4' high exert the same pressure as a 1″ column 4' high?
       
      Linus

      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #72327
      Tor
      Participant

      Ah, but does a 4″ column of Cruzan rum exert the same force as a quart of Mount Gay? This is the question that has plagued Caribbean sailors since the days of yore, or at least since April Fool’s Day.

      Tor
      ~~~~~~~~~~~~~~~~~~~~~~~
      Silver Heels, P-424 #17
      http://www.SilverHeels.us
      ~~~~~~~~~~~~~~~~~~

      Quote:

      Original Message


      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #72334
      unabated
      Participant

      The holding tank vent on my old Catalina 30 went up into a stanchion. It had a pipe welded to the bottom of the stanchion that went through the deck. I like that idea so much, I added another stanchion just like it to vent the water tank.
      alan

      — On Wed, 4/1/09, <> wrote:

      Quote:
      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #72340
      Syringa
      Participant

      Thanks Rich

      I looked over the system and will be running the vent to the aft bilge.

Viewing 12 reply threads
  • You must be logged in to reply to this topic.