Forums › General Discussion › Stove solenoid

Viewing 5 reply threads
  • Author
    Posts
    • #68083
      Anonymous

      Hi everyone. My boat was delivered new in 1982 with an installed propane
      system. The propane jugs are outside in a locker, with an electric solenoid
      to open the line. There’s also a regulator and a selector (two tanks).

      There’s a second solenoid nearer to the stove. The idea is if something goes
      wrong at the stove, one can turn a switch at the stove and turn off the gas
      flow closer than the rear locker.

      Does anyone know where that second solenoid is mounted, before I waste a lot
      of time looking?

      Thanks.

      _______________________________________________
      maillist mailing list

      https://pearson424.org/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

    • #75751
      john stevenson
      Participant

      Thatcher,
      Mine is located in the forward end of the locker outboard of the stove. I
      have the L-shaped galley so my stove is further forward than those with the
      U-shaped galley. I would guess it is directly above your stove locations.

      On Thu, Jul 22, 2010 at 12:06 PM, Thatcher A. Stone, Esquire – Confidential
      Attorney Communication <> wrote:

      Hi everyone. My boat was delivered new in 1982 with an installed propane
      system. The propane jugs are outside in a locker, with an electric solenoid
      to open the line. There’s also a regulator and a selector (two tanks).

      There’s a second solenoid nearer to the stove. The idea is if something
      goes
      wrong at the stove, one can turn a switch at the stove and turn off the gas
      flow closer than the rear locker.

      Does anyone know where that second solenoid is mounted, before I waste a
      lot
      of time looking?

      Thanks.

      _______________________________________________
      maillist mailing list

      https://pearson424.org/mailman/listinfo/maillist_pearson424.org

      —
      Regards,
      John Stevenson
      http://www.svsarah.com
      _______________________________________________
      maillist mailing list

      https://pearson424.org/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

    • #75752
      patn
      Moderator

      We have a U shaped galley – also vintage 1982. The solenoid is forward
      of the stove behind the “smoked glass” in a small compartment, just aft
      the salon locker.

      – pat

      John Stevenson wrote, On 7/22/10 12:09 PM:

      Thatcher,
      Mine is located in the forward end of the locker outboard of the stove. I
      have the L-shaped galley so my stove is further forward than those with the
      U-shaped galley. I would guess it is directly above your stove locations.

      On Thu, Jul 22, 2010 at 12:06 PM, Thatcher A. Stone, Esquire – Confidential
      Attorney Communication<> wrote:

      Hi everyone. My boat was delivered new in 1982 with an installed propane
      system. The propane jugs are outside in a locker, with an electric solenoid
      to open the line. There’s also a regulator and a selector (two tanks).

      There’s a second solenoid nearer to the stove. The idea is if something
      goes
      wrong at the stove, one can turn a switch at the stove and turn off the gas
      flow closer than the rear locker.

      Does anyone know where that second solenoid is mounted, before I waste a
      lot
      of time looking?

      Thanks.

      _______________________________________________
      maillist mailing list

      https://pearson424.org/mailman/listinfo/maillist_pearson424.org

      _______________________________________________
      maillist mailing list

      https://pearson424.org/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

    • #75753
      unabated
      Participant

      Hull 140, U shaped galley.
      The solenoid is forward of the stove, forward of the wall that separates the smoked glass locker and the locker that is in the salon. I had to remove the shelves in the smoked glass locker before removing the teak panel. I had to replace the old copper line with a new hose.
      Alan

      — On Thu, 7/22/10, pat noordsij <> wrote:

      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #75754
      Anonymous

      Thanks Pat, I have the U too. Is your switch and red light on the wall
      forward of the stove? If so, where in relation to that switch is the
      solenoid/ Thanks.


      Original Message


      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

    • #75755
      Anonymous

      Thanks Alan.


      Original Message


      <.. snip>

      Post generated from Pearson424 Forum using Mail2Forum

Viewing 5 reply threads