Forums › General Discussion › Water tank problems
- This topic has 13 replies, 9 voices, and was last updated 18 years, 4 months ago by
Jack Clarke.
-
AuthorPosts
-
-
June 17, 2008 at 2:04 pm #67061
RichCarterParticipantOne of the recurring threads of this topic is the difficulty in determining the tank level when filling. If you can’t determine level, it is easy to overfill. I’ve looked for a reasonably priced level gauge for the water tanks and have yet to find anything. If you are in the process of replacing the access plates, now would be a good time to consider adding a gauge. If anyone comes across a good solution, please let me know.
—
Rich Carter
BlackSheep #47
To unsubscribe, e-mail:
For additional commands, e-mail:Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 2:08 pm #70201
Anonymous
Rich, have you checked out the SCADtech tank monitors (I did *not*
design these myself but we are the distributor of them and they got very
good reviews in Practical Sailor).Pete
http://www.sailorssolutions.com/index.asp?page=Products&SubCategoryID=81
wrote:
One of the recurring threads of this topic is the difficulty in determining the tank level when filling. If you can’t determine level, it is easy to overfill. I’ve looked for a reasonably priced level gauge for the water tanks and have yet to find anything. If you are in the process of replacing the access plates, now would be a good time to consider adding a gauge. If anyone comes across a good solution, please let me know.
—
Rich Carter
BlackSheep #47
To unsubscribe, e-mail:
For additional commands, e-mail:
To unsubscribe, e-mail:
For additional commands, e-mail:Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 2:18 pm #70202
unabated
ParticipantI put a set of SnakeRiver tank sensors on last year.
The 4 tank model.
Can’t get more reasonable in price or ease of install.
http://www.snake-river.org/Products.asp
ap
— wrote:One of the recurring threads of this topic is the
difficulty in determining the tank level when
filling. If you can’t determine level, it is easy
to overfill. I’ve looked for a reasonably priced
level gauge for the water tanks and have yet to find
anything. If you are in the process of replacing
the access plates, now would be a good time to
consider adding a gauge. If anyone comes across a
good solution, please let me know.
—
Rich Carter
BlackSheep #47
To unsubscribe, e-mail:
For additional commands, e-mail:
To unsubscribe, e-mail:
For additional commands, e-mail:Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 2:29 pm #70203
RichCarterParticipantPete
Thanks for the reply. My checkbook says that this is an expensive solution. The gauge alone runs $240. I was thinking of a more cost effective gauge. A simple sight-tube is all you need, but it would be difficult to mount. You can get mechanical fuel gauges similar to what the 424 has for about $30 ea. I don’t know what would happen to them if you used them in a water tank however.Here’s one with a remote gauge for $40.
http://www.defender.com/product.jsp?path=-1|311|302335|7364|939818|940755&id=940380—
Rich Carter
Original message
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 3:05 pm #70204
madsailor
ModeratorHi Rich,
The absolute simplest way is to make sure the inspection plates are water tight and the vents loop into the bilge several inches below the deck. Then you fill the tanks until they overflow and presto- no more worries. That's what I do.
I'm also installing the SCADtech monitors, but it's taking longer than I expected because other stuff comes up.
Bob
On Tue, Jun 17, 2008 at 7:04 AM, < ([email][/email])> wrote:
One of the recurring threads of this topic is the difficulty in determining the tank level when filling. If you can't determine level, it is easy to overfill. I've looked for a reasonably priced level gauge for the water tanks and have yet to find anything. If you are in the process of replacing the access plates, now would be a good time to consider adding a gauge. If anyone comes across a good solution, please let me know.
—
Rich Carter
BlackSheep #47
To unsubscribe, e-mail: ()
For additional commands, e-mail: ()—
Bob Fine
Fine Software LLC
Your data on the web your way. No kiddingPost generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 3:32 pm #70205
Anonymous
I installed Tank Tender-advertised in several boating magazines-in 1985. I have all three tanks connected and it works great. It does not use any power, only air pressure, and is trouble free. Youc can also connect it to your other tanks if you wish. Jim, Revery Cutter #219
— wrote:
<.. snip>
Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 5:16 pm #70206
Hull152_Patrick
Spectatorhttp://www.thetanktender.com/about.htm
That actually looks pretty simple to install.-p
Original Message
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
Owners no more...
Thanks Dawn and Patrick! -
June 17, 2008 at 6:38 pm #70207
unabated
Participantbut look at the price to do 4 tanks……yikes
alan
— Patrick Walters <> wrote:Quote:http://www.thetanktender.com/about.htm
That actually looks pretty simple to install.-p
Original Message
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 11:09 pm #70208
Anonymous
My boat also has a tank tender on it from PO. It works fine but you
need to know that it is not a direct readout. It reads out in inches of
pressure and then you have to look at your self-created conversion table
for each tank. Not that bad, works will, (you use a little piston pump
on the panel to pump air in to clear the tube and then read the
pressure) but amazingly expensive for the multi-tank switch manifolds.Pete
alan P wrote:
Quote:but look at the price to do 4 tanks……yikes
alan
— Patrick Walters <> wrote:Quote:http://www.thetanktender.com/about.htm
That actually looks pretty simple to install.-p
Original Message
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
-
June 17, 2008 at 11:14 pm #70209
svtopaz
ParticipantI found a kink in the overflow loop. I replaced it but have not check to see if it makes a diference. I am going to put new o-rings in. I would love to have the stainless plates but it is to much $$$. Same with the gauges. The hose I replaced was very dirty and very old. Some one also told me about a fitting I can put on my hose to keep the pressure at a certain level. Think I will look into that also.
Barbara
-
June 18, 2008 at 2:29 am #70210
rdugger
ParticipantI installed the 1-8 tank SCAD monitor this winter with sensors on 2 of the 3 water tanks. I liked the potential to add fuel, waste and propane at a later date. Installation was not bad. Instructions were very precise and clear. So far it works as advertised.
Rick
Eclipse #73On Tue, Jun 17, 2008 at 6:14 PM, svtopaz < ([email][/email])> wrote:
I found a kink in the overflow loop. I replaced it but have not check to see if it makes a diference. I am going to put new o-rings in. I would love to have the stainless plates but it is to much $$$. Same with the gauges. The hose I replaced was very dirty and very old. Some one also told me about a fitting I can put on my hose to keep the pressure at a certain level. Think I will look into that also.
Barbara
Post generated from Pearson424 Forum using Mail2Forum
-
June 18, 2008 at 10:56 am #70212
madsailor
ModeratorHi Rick,
Good to know – mine is 'in progress' – the monitor is mounted and the holding tank is taped. Wiring and sensors for other tanks coming real soon now.
Bob
On Tue, Jun 17, 2008 at 7:29 PM, Rick Dugger < ([email][/email])> wrote:
I installed the 1-8 tank SCAD monitor this winter with sensors on 2 of the 3 water tanks. I liked the potential to add fuel, waste and propane at a later date. Installation was not bad. Instructions were very precise and clear. So far it works as advertised.
Rick
Eclipse #73On Tue, Jun 17, 2008 at 6:14 PM, svtopaz < ([email][/email])> wrote:
I found a kink in the overflow loop. I replaced it but have not check to see if it makes a diference. I am going to put new o-rings in. I would love to have the stainless plates but it is to much $$$. Same with the gauges. The hose I replaced was very dirty and very old. Some one also told me about a fitting I can put on my hose to keep the pressure at a certain level. Think I will look into that also.
Barbara
—
Bob Fine
Fine Software LLC
Your data on the web your way. No kiddingPost generated from Pearson424 Forum using Mail2Forum
-
June 19, 2008 at 3:25 pm #70221
sumocean
ParticipantRich
It seems like it would be easy to plumb a clear tube from a Tee off the
supply line at the bottom of the tank and run back into the top of the tank.
The problem would locating it in a spot where it would be easy to see and at
the same level as the tank. When I saw the door added at the aft end of the
tank I thought that it would be a great spot for a sight glass that would be
an accurate way to check the level without having to remove the inspection
port on top of the tank. I haven’t done this yet as I am trying to get the
boat ready to use after the repower. Maybe this winter I can jump into this
one.Linus
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
-
June 19, 2008 at 4:41 pm #70222
Jack Clarke
ParticipantThe PO of Xanadu ran the looped vent lines from the tee of the main tanks up through the cabin sole against the inboard side of the fridge. The loop goes all the way to the top edge of the fridge and you can read the water level in the tanks through the clear hose. There are indicator marks on the side of the fridge to tell how much water is in the tanks. It's not real accurate, but it's close enough. When I fill the tanks I just listen to the sound of the water in the fill hoses. If there is a spill, it's very little and I use that opportunity to clean the cabin sole. When the boat is heeled I've never had any water leak from the vented loop. The whole set up is under $5.
Jack Clarke
Xanadu IVOn 6/19/08, Linus Sumocean < ([email][/email])> wrote:
Quote:RichIt seems like it would be easy to plumb a clear tube from a Tee off the supply line at the bottom of the tank and run back into the top of the tank. The problem would locating it in a spot where it would be easy to see and at the same level as the tank. When I saw the door added at the aft end of the tank I thought that it would be a great spot for a sight glass that would be an accurate way to check the level without having to remove the inspection port on top of the tank. I haven't done this yet as I am trying to get the boat ready to use after the repower. Maybe this winter I can jump into this one.
Linus
<.. snip>Post generated from Pearson424 Forum using Mail2Forum
-
-
AuthorPosts
- You must be logged in to reply to this topic.