Forums › General Discussion › Overcharging problems

Viewing 10 reply threads
  • Author
    Posts
    • #68429
      Hull152_Patrick
      Spectator

      Not sure if I said or not but we tried to leave Coos Bay andhad to head back
      due to additional problems with the charging, basically we were boiling our
      startingf battery. Here’s a write up on what we think happened and how we
      corrected it. May this not happen to you any of you… πŸ™‚
      http://deepplaya.com/?p=650

      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya
      _______________________________________________
      maillist mailing list

      http://server12.websitehostserver.net/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

      Owners no more...
      Thanks Dawn and Patrick!

    • #77749
      unabated
      Participant

      I have always have had the Alternator charging the house bank – it’s theΒ  biggest need.
      When you think about it, you only crank the start battery for a few seconds and really don’t take much power from it. SO .. I set it up to charge the house bank – the ACR is set up to turn ON when it sees a voltage condition from the Alternator over a certain level. Because the sense wire is on the house bank.Β  When that happens, the contacts close and charges the starting battery “at the same time”.
      Probably 100% of the time the house bank is going to be at a much lower level (discharged) then the starting battery ( unless your really cranking and having trouble starting the engine. In which case your probably going to be using the battery switch to combine the the house bank and starting bank anyhow.
      Alan
      Β 

      — On Sun, 9/25/11, Patrick “Peaboy” Walters wrote:

      Post generated from Pearson424 Forum using Mail2Forum

    • #77750
      madsailor
      Moderator

      Hi Pat,

      Alan is correct. Use the house bank for monitoring and charging, using the
      ACR to charge the start battery. After all, you can start the engine with
      the house bank, I hope, but not run ship’s loads with the engine start
      battery.

      Also, make sure you have all the same type of batteries. Don’t do flooded
      for engine start and AGM for house. You may have mentioned the types, so
      this could be an unuseful comment.

      Good luck. It’s good to have 660 hours – I have that (almost) in 3 – 4D
      batteries and seldom go much below about 80% charged – with the new solar
      panels, not even that. I have two group 31s for emergency start and radio
      operation. Normally, I use the house bank exclusively with the other tested
      by starting the engine whenever I think about it.

      Bob

      On Mon, Sep 26, 2011 at 6:33 AM, Alan wrote:

      Quote:
      I have always have had the Alternator charging the house bank – it’s the
      biggest need.
      When you think about it, you only crank the start battery for a few seconds
      and really don’t take much power from it. SO .. I set it up to charge the
      house bank – the ACR is set up to turn ON when it sees a voltage condition
      from the Alternator over a certain level. Because the sense wire is on the
      house bank. When that happens, the contacts close and charges the starting
      battery “at the same time”.
      Probably 100% of the time the house bank is going to be at a much lower
      level (discharged) then the starting battery ( unless your really cranking
      and having trouble starting the engine. In which case your probably going to
      be using the battery switch to combine the the house bank and starting bank
      anyhow.
      Alan

      — On Sun, 9/25/11, Patrick “Peaboy” Walters
      wrote:

      Post generated from Pearson424 Forum using Mail2Forum

    • #77751
      quent
      Participant

      I would be inclined to put both the VR and ACR sense wires on the alternator output, with the alternator output to the house bank and the ACR closing the circuit to the start battery when it senses alternator charging voltage.
      Sounds like you might have a voltage drop problem between the battery being sensed by the VR and the alternator. This would cause the battery accepting less current to be at higher voltage. Try checking the connections and make sure the wire guage taking the charge current to the house bank is adequate, and check the voltages at the alternator, the house bank and the starter when you are in “cooking” mode.
      Quent

    • #77753
      petedd
      Participant

      Is your regulator set to the right battery type?

      On 9/25/2011 9:53 PM, Patrick “Peaboy” Walters wrote:

      Not sure if I said or not but we tried to leave Coos Bay andhad to head back
      due to additional problems with the charging, basically we were boiling our
      startingf battery. Here’s a write up on what we think happened and how we
      corrected it. May this not happen to you any of you… πŸ™‚
      http://deepplaya.com/?p=650

      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya
      _______________________________________________
      maillist mailing list

      http://server12.websitehostserver.net/mailman/listinfo/maillist_pearson424.org

      _______________________________________________
      maillist mailing list

      http://server12.websitehostserver.net/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

    • #77754
      Hull152_Patrick
      Spectator

      Thanks for all the ideas let me try and answer the questions and provide a
      bit more background.

      I originally thought you were supposed to put all the charge inputs on the
      house and use the ACR to charge the starting battery as well. The guy here
      at the local Chandlery convinced me it was more important to ensure the
      starting battery was serviced first in case of a failure of the ACR, which
      made sense to me. So we wired the alternator to the starting battery. We now
      definitely know it was wrong to have the 12V sensor wire and the charge
      loads on different sides of the ACR. Read about that in the blog post. The
      question now is it OK to rely on the ACR to charge the house battery…
      everyone seems to say we shouldn’t do it that way (including Rich at Balmar)
      but I’ve not heard a technical reason why. Seems like as long as the ACR
      combines you’re charging everything anyway… The ACR isnt’ a “smart”
      combiner that uncombines when the 2nd bank is full.

      Anyway, I am thinking I’ll go that route anyway so we’re in compliance with
      the normal way. In fact, I’m thinking I might get rid of the ACR from the
      system and add a smarter combiner like the Balmar
      Duo-Charge or
      Xantrex Echo Chargesomeone
      else mentioned. They seem even smarter than the ACR. Going to
      confirm with Monty today and make a decision before shipping for the day
      ends.

      *Quent*, I don’t think it was a voltage drop issue. I used 2/0 wire all
      under 12′ lengths. The original problem was a timing issue of the ACR not
      combining the batteries while the regulator was sensing one bank and
      charging another.

      *Pete*, the regulator is on the defaults now which is the Universal Factory
      Program (UFP) which should be fine for all batteries. I’ll switch to the
      flooded mode for sure, but the UFP shouldn’t cause any issues.

      Someone asked about the type of the starting battery. The new starting
      battery is a sealed lead acid. It’s not an AGM.

      Like I mentioned I think we’re going to wire everything to the house bank
      and use the ACR or a smarter combiner to charge the starting battery.

      Looks like the weather is bad till Thursday, so plenty of time to get this
      right! πŸ™‚
      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya

      On Mon, Sep 26, 2011 at 4:09 AM, Robert Fine wrote:

      Hi Pat,

      Alan is correct. Use the house bank for monitoring and charging, using the
      ACR to charge the start battery. After all, you can start the engine with
      the house bank, I hope, but not run ship’s loads with the engine start
      battery.

      Also, make sure you have all the same type of batteries. Don’t do flooded
      for engine start and AGM for house. You may have mentioned the types, so
      this could be an unuseful comment.

      Good luck. It’s good to have 660 hours – I have that (almost) in 3 – 4D
      batteries and seldom go much below about 80% charged – with the new solar
      panels, not even that. I have two group 31s for emergency start and radio
      operation. Normally, I use the house bank exclusively with the other
      tested
      by starting the engine whenever I think about it.

      Bob

      On Mon, Sep 26, 2011 at 6:33 AM, Alan wrote:

      I have always have had the Alternator charging the house bank – it’s the
      biggest need.
      When you think about it, you only crank the start battery for a few

      seconds

      and really don’t take much power from it. SO .. I set it up to charge the
      house bank – the ACR is set up to turn ON when it sees a voltage

      condition

      from the Alternator over a certain level. Because the sense wire is on

      the

      house bank. When that happens, the contacts close and charges the

      starting

      battery “at the same time”.
      Probably 100% of the time the house bank is going to be at a much lower
      level (discharged) then the starting battery ( unless your really

      cranking

      and having trouble starting the engine. In which case your probably going

      to

      be using the battery switch to combine the the house bank and starting

      bank

      Quote:
      anyhow.
      Alan

      — On Sun, 9/25/11, Patrick “Peaboy” Walters
      wrote:

      Post generated from Pearson424 Forum using Mail2Forum

      Owners no more...
      Thanks Dawn and Patrick!

    • #77755
      john stevenson
      Participant

      Patrick,
      Just so you know you have company, my ACR is wired as yours was – alternator
      output to the start bank, then to the house bank when the starting battery
      voltage > 13.1 VDC. Like you, I thought it made sense to treat the start
      battery as the critical bank.

      Then the original combiner (a Yandina, not Blue Sea) failed. In the middle
      of the night my crew woke me to say the entire boat just went dark – chart
      plotter, autopilot, instruments and lights. I checked the batteries and
      sure enough the house bank was under 10.5 VDC and the starter bank was
      really happy at 13.6 VDC. It took me a few minutes to realize the combiner
      had failed and only the starter bank was getting a charge. Then I threw the
      switch to combine the batteries on the backside of the combiner. A few
      seconds later all of the electronics were back in operation and I could go
      back to sleep.

      Strangely enough, when I replaced the failed Yandina with the Blue Sea ACR I
      still kept the Starter bank as the primary for charging. I still wasn’t
      convinced it was the wrong way to go. Subsequent thinking and reading on
      this issue has convinced me I have it backwards, just haven’t gotten around
      to re-wiring. I also bought the remote control switch for the Blue Sea ACR
      to manually combine the batteries. That hasn’t been installed either. I do
      like to think hard and long on these projects. Some would call it
      procrastination. I prefer to think of it as the thoroughness of a
      craftsman.

      Regards,
      John Stevenson
      http://www.svsarah.com

      On Mon, Sep 26, 2011 at 3:25 PM, Patrick “Peaboy” Walters <
      > wrote:

      Thanks for all the ideas let me try and answer the questions and provide a
      bit more background.

      I originally thought you were supposed to put all the charge inputs on the
      house and use the ACR to charge the starting battery as well. The guy here
      at the local Chandlery convinced me it was more important to ensure the
      starting battery was serviced first in case of a failure of the ACR, which
      made sense to me. So we wired the alternator to the starting battery. We
      now
      definitely know it was wrong to have the 12V sensor wire and the charge
      loads on different sides of the ACR. Read about that in the blog post. The
      question now is it OK to rely on the ACR to charge the house battery…
      everyone seems to say we shouldn’t do it that way (including Rich at
      Balmar)
      but I’ve not heard a technical reason why. Seems like as long as the ACR
      combines you’re charging everything anyway… The ACR isnt’ a “smart”
      combiner that uncombines when the 2nd bank is full.

      Anyway, I am thinking I’ll go that route anyway so we’re in compliance with
      the normal way. In fact, I’m thinking I might get rid of the ACR from the
      system and add a smarter combiner like the Balmar
      Duo-Charge or
      Xantrex Echo Charge<
      http://www.xantrex.com/power-products/power-accessories/auxiliary-battery-charger.aspx

      someone

      else mentioned. They seem even smarter than the ACR. Going to
      confirm with Monty today and make a decision before shipping for the day
      ends.

      *Quent*, I don’t think it was a voltage drop issue. I used 2/0 wire all
      under 12′ lengths. The original problem was a timing issue of the ACR not
      combining the batteries while the regulator was sensing one bank and
      charging another.

      *Pete*, the regulator is on the defaults now which is the Universal Factory
      Program (UFP) which should be fine for all batteries. I’ll switch to the
      flooded mode for sure, but the UFP shouldn’t cause any issues.

      Someone asked about the type of the starting battery. The new starting
      battery is a sealed lead acid. It’s not an AGM.

      Like I mentioned I think we’re going to wire everything to the house bank
      and use the ACR or a smarter combiner to charge the starting battery.

      Looks like the weather is bad till Thursday, so plenty of time to get this
      right! πŸ™‚
      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya

      On Mon, Sep 26, 2011 at 4:09 AM, Robert Fine wrote:

      Hi Pat,

      Alan is correct. Use the house bank for monitoring and charging, using

      the

      ACR to charge the start battery. After all, you can start the engine

      with

      the house bank, I hope, but not run ship’s loads with the engine start
      battery.

      Also, make sure you have all the same type of batteries. Don’t do

      flooded

      for engine start and AGM for house. You may have mentioned the types, so
      this could be an unuseful comment.

      Good luck. It’s good to have 660 hours – I have that (almost) in 3 – 4D
      batteries and seldom go much below about 80% charged – with the new solar
      panels, not even that. I have two group 31s for emergency start and

      radio

      operation. Normally, I use the house bank exclusively with the other
      tested
      by starting the engine whenever I think about it.

      Bob

      On Mon, Sep 26, 2011 at 6:33 AM, Alan wrote:

      I have always have had the Alternator charging the house bank – it’s

      the

      biggest need.
      When you think about it, you only crank the start battery for a few

      seconds

      and really don’t take much power from it. SO .. I set it up to charge

      the

      house bank – the ACR is set up to turn ON when it sees a voltage

      condition

      from the Alternator over a certain level. Because the sense wire is on

      the

      house bank. When that happens, the contacts close and charges the

      starting

      battery “at the same time”.
      Probably 100% of the time the house bank is going to be at a much lower
      level (discharged) then the starting battery ( unless your really

      cranking

      and having trouble starting the engine. In which case your probably

      going

      to

      be using the battery switch to combine the the house bank and starting

      bank

      Quote:
      anyhow.
      Alan

      — On Sun, 9/25/11, Patrick “Peaboy” Walters
      wrote:

      Post generated from Pearson424 Forum using Mail2Forum

    • #77756
      Hull152_Patrick
      Spectator

      The guy at Englund is really convinced you charge the starting battery
      first, it was actually getting a little uncomfortable talking about it.

      The guy from Balmar was adamant that the MC614 was a house bank charge
      regulator (huh?) and we should be using a Duo-Charge (or the ACR) to charge
      the start battery, not the other way around.

      Everyone seems baffled the ACR could have caused this but in reading the
      manual I think I see why:

      “Internal time delay prevents relay action for transient conditions, voltage

      must be within range for approximately one minute to cause closure, relay
      will open when overvoltage is detected for approximately 15 seconds.”

      When I reproduced this at the dock, the voltage definitely ramped up in less
      than a minute. Moving the sensor wire to be on the same side as the charge
      voltage, regardless if its the start or house bank, will eliminate the
      regulator from doing that.

      I think I’m going to get out of dodge as-is and get some more input in
      California.

      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya

      On Mon, Sep 26, 2011 at 1:32 PM, John Stevenson wrote:

      Patrick,
      Just so you know you have company, my ACR is wired as yours was –
      alternator
      output to the start bank, then to the house bank when the starting battery
      voltage > 13.1 VDC. Like you, I thought it made sense to treat the start
      battery as the critical bank.

      Then the original combiner (a Yandina, not Blue Sea) failed. In the middle
      of the night my crew woke me to say the entire boat just went dark – chart
      plotter, autopilot, instruments and lights. I checked the batteries and
      sure enough the house bank was under 10.5 VDC and the starter bank was
      really happy at 13.6 VDC. It took me a few minutes to realize the combiner
      had failed and only the starter bank was getting a charge. Then I threw
      the
      switch to combine the batteries on the backside of the combiner. A few
      seconds later all of the electronics were back in operation and I could go
      back to sleep.

      Strangely enough, when I replaced the failed Yandina with the Blue Sea ACR
      I
      still kept the Starter bank as the primary for charging. I still wasn’t
      convinced it was the wrong way to go. Subsequent thinking and reading on
      this issue has convinced me I have it backwards, just haven’t gotten around
      to re-wiring. I also bought the remote control switch for the Blue Sea ACR
      to manually combine the batteries. That hasn’t been installed either. I
      do
      like to think hard and long on these projects. Some would call it
      procrastination. I prefer to think of it as the thoroughness of a
      craftsman.

      Regards,
      John Stevenson
      http://www.svsarah.com

      On Mon, Sep 26, 2011 at 3:25 PM, Patrick “Peaboy” Walters <
      > wrote:

      Thanks for all the ideas let me try and answer the questions and provide

      a

      bit more background.

      I originally thought you were supposed to put all the charge inputs on

      the

      house and use the ACR to charge the starting battery as well. The guy

      here

      at the local Chandlery convinced me it was more important to ensure the
      starting battery was serviced first in case of a failure of the ACR,

      which

      made sense to me. So we wired the alternator to the starting battery. We
      now
      definitely know it was wrong to have the 12V sensor wire and the charge
      loads on different sides of the ACR. Read about that in the blog post.

      The

      question now is it OK to rely on the ACR to charge the house battery…
      everyone seems to say we shouldn’t do it that way (including Rich at
      Balmar)
      but I’ve not heard a technical reason why. Seems like as long as the ACR
      combines you’re charging everything anyway… The ACR isnt’ a “smart”
      combiner that uncombines when the 2nd bank is full.

      Anyway, I am thinking I’ll go that route anyway so we’re in compliance

      with

      the normal way. In fact, I’m thinking I might get rid of the ACR from the
      system and add a smarter combiner like the Balmar
      Duo-Charge or
      Xantrex Echo Charge<

      http://www.xantrex.com/power-products/power-accessories/auxiliary-battery-charger.aspx

      someone

      else mentioned. They seem even smarter than the ACR. Going to
      confirm with Monty today and make a decision before shipping for the day
      ends.

      *Quent*, I don’t think it was a voltage drop issue. I used 2/0 wire all
      under 12′ lengths. The original problem was a timing issue of the ACR not
      combining the batteries while the regulator was sensing one bank and
      charging another.

      *Pete*, the regulator is on the defaults now which is the Universal

      Factory

      Program (UFP) which should be fine for all batteries. I’ll switch to the
      flooded mode for sure, but the UFP shouldn’t cause any issues.

      Someone asked about the type of the starting battery. The new starting
      battery is a sealed lead acid. It’s not an AGM.

      Like I mentioned I think we’re going to wire everything to the house bank
      and use the ACR or a smarter combiner to charge the starting battery.

      Looks like the weather is bad till Thursday, so plenty of time to get

      this

      right! πŸ™‚
      -p

      —
      s/v Deep Playa | Pearson 424 Hull #152 | http://www.DeepPlaya.com | @DeepPlaya

      On Mon, Sep 26, 2011 at 4:09 AM, Robert Fine wrote:

      Hi Pat,

      Alan is correct. Use the house bank for monitoring and charging, using

      the

      ACR to charge the start battery. After all, you can start the engine

      with

      the house bank, I hope, but not run ship’s loads with the engine start
      battery.

      Also, make sure you have all the same type of batteries. Don’t do

      flooded

      for engine start and AGM for house. You may have mentioned the types,

      so

      this could be an unuseful comment.

      Good luck. It’s good to have 660 hours – I have that (almost) in 3 –

      4D

      batteries and seldom go much below about 80% charged – with the new

      solar

      panels, not even that. I have two group 31s for emergency start and

      radio

      operation. Normally, I use the house bank exclusively with the other
      tested
      by starting the engine whenever I think about it.

      Bob

      On Mon, Sep 26, 2011 at 6:33 AM, Alan wrote:

      I have always have had the Alternator charging the house bank – it’s

      the

      biggest need.
      When you think about it, you only crank the start battery for a few

      seconds

      and really don’t take much power from it. SO .. I set it up to charge

      the

      house bank – the ACR is set up to turn ON when it sees a voltage

      condition

      from the Alternator over a certain level. Because the sense wire is

      on

      the

      house bank. When that happens, the contacts close and charges the

      starting

      battery “at the same time”.
      Probably 100% of the time the house bank is going to be at a much

      lower

      level (discharged) then the starting battery ( unless your really

      cranking

      and having trouble starting the engine. In which case your probably

      going

      to

      be using the battery switch to combine the the house bank and

      starting

      bank

      anyhow.
      Alan

      — On Sun, 9/25/11, Patrick “Peaboy” Walters <

      Quote:
      Quote:
      wrote:

      Post generated from Pearson424 Forum using Mail2Forum

      Owners no more...
      Thanks Dawn and Patrick!

    • #77757
      quent
      Participant

      Regarding which bank to hook to the switched side of the combiner, if you have a large house bank, anchor for a couple days, then start the engine, the house bank is going to suck up most of the alternator output. The start battery, if everything is working right, will be already well charged and quickly replace the small discharge required to start the engine.
      I really don’t think you want the much larger current to the house bank going through the switch in the combiner.
      Since the VR sense lead needs to be on the alternator side of the combiner switch, any voltage drop in the combiner will reduce charging efficiency on the switched bank. No big deal on the start battery, but a problem on the house bank
      You might also want to get one of those IR thermometers and check the connections for heat.
      John: Jumper cables.
      Quent

    • #77758
      Hull152_Patrick
      Spectator

      Checking the heat is a good suggestion. I’m going to leave everything as-is
      for now. I think we’re going to upgrade our Solar capacity and if needed
      replace our batteries in San Diego so I’ll make this all “right” (whetever
      that means) at that time.

      -p

      On Mon, Sep 26, 2011 at 4:14 PM, quent wrote:

      Regarding which bank to hook to the switched side of the combiner, if you
      have a large house bank, anchor for a couple days, then start the engine,
      the house bank is going to suck up most of the alternator output. The start
      battery, if everything is working right, will be already well charged and
      quickly replace the small discharge required to start the engine.
      I really don’t think you want the much larger current to the house bank
      going through the switch in the combiner.
      Since the VR sense lead needs to be on the alternator side of the combiner
      switch, any voltage drop in the combiner will reduce charging efficiency on
      the switched bank. No big deal on the start battery, but a problem on the
      house bank
      You might also want to get one of those IR thermometers and check the
      connections for heat.
      John: Jumper cables.
      Quent

      _______________________________________________
      maillist mailing list

      http://server12.websitehostserver.net/mailman/listinfo/maillist_pearson424.org

      _______________________________________________
      maillist mailing list

      http://server12.websitehostserver.net/mailman/listinfo/maillist_pearson424.org

      Post generated from Pearson424 Forum using Mail2Forum

      Owners no more...
      Thanks Dawn and Patrick!

    • #77761
      Chuck Ruble
      Participant

      Patrick, stick with the ACR. It is pretty simple and if I’m not mistake does not have the amperage limitations the Duo-Charge has.

      Chuck